HVB AE Power Systems Supplies Wide Array of Substation Equipment

HVB AE Power Systems, Inc., host of the 2009 Finepoint Circuit Breaker Test and Maintenance Conference Factory Day, is not just a domestic high-voltage circuit breaker manufacturer but also plays an important role as an international supplier with a wide array of substation equipment. In 2008, the first dead-tank type 800kV GCB was delivered to a U.S. customer, and several units have been supplied continuously since then.

.

Gas Circuit Breakers (72kV - 550kV)

  • Dead Tank designs

  • Can place bushing current transformers on both sides of Interrupter

  • Seismic withstand capabilities

  • Isolated phase interruption

  • Low temperature capabilities

  • Conforms to ANSI, IEEE and IEC Standards

  • Both steel and aluminum tank designs built to meet ASME

  • Voltages from 69 to 550kV.

  • Interrupting ratings up through 63kA.

  • Continuous currents through 4,000A.

  • Spring and pneumatic mechanisms.

  • Gang and independent pole operation designs available

Gas Insulated Switchgear (69kV - 500kV)

  • Dead Tank designs

  • Can place bushing current transformers on both sides of Interrupter

  • Seismic withstand capabilities

  • Isolated phase interruption

  • Low temperature capabilities

  • Conforms to ANSI, IEEE and IEC Standards

  • Both steel and aluminum tank designs built to meet ASME

  • Voltages from 24 to 36V

  • Interrupting ratings up through 31.5kA

  • Continuous currents through 2,500A

  • Spring mechanisms

Generator Main Circuit Breakers

  • Dead tank construction
  • Can place bushing current transformers on both sides of interrupter
  • Seismic withstand capabilities
  • Isolated phase interruption
  • Disconnect and grounding switches are options

Want to use this article? Click here for options!
© 2012 Penton Media Inc.


Acceptable Use Policy

Comments are the sole responsibility of the person posting them. T&D World will not edit postings. If T&D World editors deem any comment inappropriate, we will preempt or remove the posting.

General Rules: T&D World will not allow comments that are found to be degrading based on gender, race, class, ethnicity, national origin, religion, sexual orientation or disability. Neither will epithets, abusive language or obscene comments be allowed.

blog comments powered by Disqus

T&D TV

Most Read


Find Other Popular Items

Features

Vegetation Management
Grid Optimization

Upcoming Webcasts

Transmission & Distribution World allows you to access live and on-demand webcasts. Webcasts are available during their scheduled date and time. If you are unable to attend at the scheduled time, these free events will be available On-Demand for viewing at your convenience.


On-Demand Webcasts

» View More Webcasts

Jobzone
  • Transmission & Distribution World May 2012 Issue
  • Transmission & Distribution World April2012 Issue
  • Transmission & Distribution World March 2012 Issue
  • Transmission & Distribution World February 2012 Issue
  • January 2012 Issue
  • December 2011 Issue
  • November 2011 Issue

Browse Back Issues