Internal Fault Detector

The IFD is an embedded mechanical sensor that activates when a sudden pressure from an internal arcing fault occurs inside the transformer.

The IFD also includes a standard pressure relief device (PRD) that is integrated into the sensor to save costs and space on the transformer tank.

During an internal fault, the rate at which the pressure rises is at least one thousand times faster than any other pressure rise that might occur. as a result of normal operating or external causes. This rapid pressure rise then becomes a reliable means to detect internal transformer faults.

When the internal fault occurs, the IFD releases a highly visible orange signal that crews can see from 60 feet (20 meters) away from the pole, even at night. The signal alerts crews that the transformer should not be re-energized, preventing a potential catastrophic failure and enhancing their safety.

The IFD reacts to a rapid pressure change of at least 0.5 psi over 5-7 milliseconds. The rapid pressure occurs only when the transformer has experienced an internal fault or short-circuit.

IFD Corp. Booth 3748

Want to use this article? Click here for options!
© 2012 Penton Media Inc.


Acceptable Use Policy

Comments are the sole responsibility of the person posting them. T&D World will not edit postings. If T&D World editors deem any comment inappropriate, we will preempt or remove the posting.

General Rules: T&D World will not allow comments that are found to be degrading based on gender, race, class, ethnicity, national origin, religion, sexual orientation or disability. Neither will epithets, abusive language or obscene comments be allowed.

blog comments powered by Disqus

Jobzone
  • Transmission & Distribution World May 2012 Issue
  • Transmission & Distribution World April2012 Issue
  • Transmission & Distribution World March 2012 Issue
  • Transmission & Distribution World February 2012 Issue
  • January 2012 Issue
  • December 2011 Issue
  • November 2011 Issue

Browse Back Issues