Tennessee Valley Authority’s 500-kV Bradley Substation Now in Service

On April 28, the automation and protection world took a giant step forward when Tennessee Valley Authority (TVA) inaugurated its Bradley Substation. The event heralds the first IEC 61850-compliant substation where all of the available features promised by the communications standard were implemented and proved to work in a 500-kV transmission substation.

Siemens provided SIPROTEC protective relays and SICAM PAS substation automation hardware and software. The Siemens configuration software, DIGSI, set the early standards and was the first commercially available IEC 61850 configuration tool.

The security features of the SIPROTEC relays include the ability to ensure that only authorized IEC 61850 clients can access the relays on this very secure network.

With many years of experience and many IEC 61850-compliant substations under its belt worldwide, Siemens took a leadership role in the Bradley Project team to help make Bradley a success. As a result, TVA now has the most cost-effective transmission protection and control design in the United States.

TVA accomplished the goals that were set out for Bradley: Use the IEC 61850 standards to reduce the number of wires, components and connections in a substation protection control house design; use the interoperability features between vendors to further reduce wiring connections and retain the benefit of having redundancy without a single mode failure problem; and reduce the costly cabling and wiring between the switchyard breakers and the control house.

"Siemens played a significant role in this development that started in 2004 as a concept and implemented to a reality in 2008," said Kevin Sullivan, vice president and general manager of Siemens Power Transmission & Distribution, Inc.'s Energy Management and Automation division. "Siemens took the leadership role in the technical implementation of the IEC 61850 standard and advised other vendors during implementation," he added.

During the final commissioning, the Siemens SIPROTEC relays identified and alerted the project team to numerous issues in the now critical communication infrastructure, which consists of various third party equipment for communication and multiple vendors' relays in addition to Siemens components.

The watchdog program in the SIPROTEC relays detected missing information caused by issues in the fiber installations and detected problems in the settings of communication switches that did not filter circulating telegrams from the system. It provides essential information of the health of the wiring connections now done through generic object oriented substation event (GOOSE) messaging on the communication network.

According to TVA Manager of Protection and Control Jim Kurtz, TVA's Bradley Substation set many "firsts" including the first 500-kV transmission implementation, first time a utility acted as the integrator, first time GOOSE messages were used for secure high speed tripping, and the first time GOOSE messages between different vendors' relays were used to realize protection logic and control.

The successful implementation of IEC 61850 is a reality now. Short lead-time, cost-effective, repeatable and flexible protection and control systems can now be designed and implemented at the highest voltage levels.

Want to use this article? Click here for options!
© 2012 Penton Media Inc.


Acceptable Use Policy

Comments are the sole responsibility of the person posting them. T&D World will not edit postings. If T&D World editors deem any comment inappropriate, we will preempt or remove the posting.

General Rules: T&D World will not allow comments that are found to be degrading based on gender, race, class, ethnicity, national origin, religion, sexual orientation or disability. Neither will epithets, abusive language or obscene comments be allowed.

blog comments powered by Disqus

T&D TV

Most Read


Find Other Popular Items

Features

Vegetation Management
Grid Optimization

Upcoming Webcasts

Transmission & Distribution World allows you to access live and on-demand webcasts. Webcasts are available during their scheduled date and time. If you are unable to attend at the scheduled time, these free events will be available On-Demand for viewing at your convenience.


On-Demand Webcasts

» View More Webcasts

Jobzone
  • Transmission & Distribution World May 2012 Issue
  • Transmission & Distribution World April2012 Issue
  • Transmission & Distribution World March 2012 Issue
  • Transmission & Distribution World February 2012 Issue
  • January 2012 Issue
  • December 2011 Issue
  • November 2011 Issue

Browse Back Issues