Resources

On Demand Media

Demand Viewing

Transmission & Distribution World On Demand events allow you to access archived webinars when it is convenient for your schedule. These free events are available for viewing 24/7.

White Papers

Designing Energy Services for Commercial and Industrial Customers

Over the past year, technology advances and high energy prices have stimulated interest in Advanced Metering Infrastructure (AMI). Discussions are wide-ranging. Some focus globally: Australian and Canadian “smart metering”, new European Union requirements, the results of time-of-use pilots that arose in the wake of California’s deregulation debacle.

More White Papers

Marketplace Ads

  • Trip Wire

    Automate NERC Cyber Security Compliance

  • Ike Blog

    Reports From The Front

Case Studies

York Region Finishes Tasks Faster

We all know that data integration improves productivity and York Region is living proof. Using AutoCAD® Map 3D, York saved time and money by relying on its AutoCAD-trained staff to quickly implement a new system that incorporates both CAD and GIS.

Save Time with CAD and GIS Integration

Read how the Public Works Department of the City of Tacoma (Tacoma), Washington, uses its geospatial data to do everything from issuing building permits and managing waste water to maintaining streetlights


         Subscribe in NewsGator Online   Subscribe in Bloglines  

Entergy Stabilizes Voltage with D-VAR

Located on a Bluff Overlooking One of the Widest Bends of the Mississippi River, Natchez is one of Mississippi's oldest cities. With its bustling tourism, strong industry and wealth of natural resources, Natchez is a desirable, small city — with a population just under 20,000. The Natchez area is served by five 115-kV transmission lines, the Natchez 75-MW gas-fired steam electric station (SES) and the Murray 20-MW hydro facility.

Entergy Mississippi Inc. (Jackson, Mississippi, U.S.) provides electricity service to approximately 427,000 customers in Mississippi across 45 counties, including Adams County in which Natchez is located. In 2005, while studying the possibility of placing the 75-MW fossil unit in reserve, Entergy identified potential dynamic voltage stability issues in the Natchez area.

PROBLEMS ON THE HORIZON

Although approximately 20 MW of generation support was still available from the nearby Murray hydro plant, steady-state studies revealed that with the Natchez SES in reserve, there could be thermal overload and low-voltage issues in the area under N-1 contingency conditions at the time of peak demand on the system. And with no reactive power support from Natchez SES, dynamic studies showed that the single-contingency loss of any one of the five lines feeding into the area could cause low voltages at various substations and slow voltage recovery following a fault. Without additional reinforcements, the dynamic studies showed that the voltage would fail to recover following a fault because of the increased reactive power demand from the area induction motor load.

Entergy determined the potential thermal overload issues could be mitigated through normal transmission reinforcement practices. Entergy conducted a feasibility study to determine if the existing 75-MW generator at Natchez SES could be converted to a synchronous condenser. The study revealed that, due to stator and rotor issues, the synchronous condenser solution would not be economical. Therefore, Entergy decided to investigate innovative solutions to address the more serious dynamic voltage stability issue.

AN EFFECTIVE SOLUTION

Voltage instability and collapse, resulting either from a lack of reactive power (VAR) support (contingencies) or from characteristics of customer load, have long been a reliability threat. Recent trends in grid development and growth in electricity demand further exacerbate these problems, making them a high priority for the electric utility industry.

Entergy system plans stipulate that sufficient reactive capacity shall be provided within the system at appropriate locations to maintain transmission-system voltages within +5% or -8% of nominal voltage under contingencies. Entergy's criteria for dynamic response are in accordance with the Western Electricity Coordinating Council's (WECC) criteria for voltage recovery.

After Entergy identified the dynamic voltage problems in the Natchez area, the utility determined solution sets that would provide effective voltage regulation under contingencies reasonably foreseeable through the summer of 2015. Given that a synchronous condenser was ruled out as a potential solution, the dynamic injection of VARs became a logical choice. The final recommendation was to install two 8-MVAR dynamic-VAR (D-VAR) units from American Superconductor Corp. (AMSC; Devens, Massachusetts, U.S.) at the 115-kV Natchez Station along with two l-MVAR capacitor banks.

The two D-VAR units control the local transmission voltage during contingencies and restore voltage to an acceptable level. The D-VAR units also control one of the capacitor banks, using it as a “contingency bank” to augment the VAR injection from the D-VARs during severe voltage dips. The selection of this particular solution was also bolstered by the fact that Entergy already had successful field experience with similar flexible ac transmission system (FACTS) devices such as static VAR compensators (SVCs) installed in Ninemile Station near New Orleans, Louisiana, U.S., and in the Woodlands area just north of Houston, Texas, U.S.

OUT IN THE FIELD

Using control and monitoring software, the D-VAR system detects and compensates for voltage disturbances by injecting leading or lagging reactive power — measured in VARs — where it is needed on the grid. These systems are scalable and can be deployed as a single large-block solution or distributed in a load area. And, inasmuch as they are modular, they can be expanded or relocated to meet future requirements.

The D-VAR solution employed by Entergy delivers continuous reactive power, controls each phase individually and has overload capability. Typically, reactive power compensation from the unit is switched on when the nominal voltage drops below a predetermined level and switched off when voltage returns to an acceptable level near the nominal voltage. At the 115-kV Natchez Station, when an undervoltage is detected, the inverter will operate continuously to provide reactive power in conjunction with the capacitor bank. If the inverter is only operated for a relatively short interval in emergency mode, the inverter may be operated in overload fashion to provide a maximum amount of reactance. Alternatively, the inverter can be operated in a steady-state mode to provide a lower reactance level over an indefinite duration.

The D-VAR solution at Natchez is capable of attenuating rapid voltage variations and can provide post-fault voltage support to mitigate any tendency for voltage collapse. The solution also functions as a fast transient voltage support device. By integrating the D-VAR output of the reactive power compensation device with mechanically switched capacitor banks, this solution is an economical alternative to SVCs and equally effective at solving common transmission grid problems such as voltage instability and voltage regulation.

INCREMENTAL CONTROL AND ECONOMICS

Historically, SVC and static synchronous compensator systems have provided the rapidly changing VARs needed to regulate voltage and quickly drive post-contingency voltages to acceptable levels. The time frame required for the solution's response is on the order of a few line cycles of ac power (one line cycle is 16.7 msec for 60-Hz ac power systems), even though they are capable of responding on a subcycle basis.

Entergy determined AMSC's solution was the most cost effective and had the fastest delivery time of all the possibilities. Both of the D-VARs were originally located in Entergy's transmission network in Texas and were operated as dynamic superconducting magnetic energy storage (D-SMES) units. Subsequent to the installation of the SVC in the Woodlands area, the D-SMES units were no longer needed there. After the decision to make use of the D-SMES units in Natchez for voltage support, the units were refurbished at AMSC and moved to Natchez to be operated as D-VAR units. Entergy saved a significant amount of capital expenditure by refurbishing and moving these units to Natchez. Other economic factors evaluated by Entergy included permitting (none required), environmental ratings, physical infrastructure (easily located in substations), and remote monitoring and control capability.


Samrat Datta joined Entergy Services Inc. in 2003 in New Orleans, Louisiana, where he currently holds the position of technical systems planning engineer, transmission planning. He holds a MSEE degree from the University of Texas at Austin and a bachelor's degree from Nagpur University, India.
sdatta@entergy.com

V. Sharma Kolluri joined Entergy Services Inc. in 1984 in New Orleans, Louisiana, where he currently holds the position of manager, technical systems planning. He holds a MSEE degree from West Virginia University and an MBA degree from the University of Dayton, Ohio. vkollur@entergy.com


Commenting terms of use

Comments are the sole responsibility of the person posting them. T&D World will not edit postings. If T&D World editors deem any comment inappropriate, we will preempt or remove the posting.

General Rules: T&D World will not allow comments that are found to be degrading based on gender, race, class, ethnicity, national origin, religion, sexual orientation or disability. Neither will epithets, abusive language or obscene comments be allowed.

blog comments powered by Disqus

Want to use this article? Click here for options!
© 2008 Penton Media Inc.

Most Read

Community

Hurricane Ike Coverage

Hurricane Ike Coverage
On September 12th, Hurricane Ike tore through the Gulf Coast, wreaking havoc on lives and property. Transmission & Distribution World’s Rick Bush is headed to the region to provide a first-hand account of the damage including an insider view of utility emergency-response efforts. His reports and subsequent feature coverage will highlight how utilities, contractors and suppliers work as a team to restore power as quickly as possible.
Read Rick’s Blog, Ike: Reports from the Front

News Releases

Briefing Room

At the Briefing Room you will be able to stay up-to-date on the latest technology announcements where we will provide daily postings from our industry sources.

Webcasts

ACSS and HS285 Extend Grid Capacity

Sponsored by Southwire

There are capacity bottleneck situations, where new overhead transmission line construction is not a practical reality. In some of these situations overhead lines are in place and they are not able to provide the transfer capacity needed.

Register Now!


Supercondutor Cable Systems

Sponsored by American Superconductor

Transmission & Distribution World presents Superconductor Cable Systems, A Part of the Increasing Bulk Power Transfer Series.

Register Now!


Evolution of Next Generation Wireless Communications in Power Delivery

Sponsored by Alcatel-Lucent

Evolution of Next Generation Wireless Communications in Power Delivery - seeing wireless communications solutions emerge to enable more efficient operations.

Register Now!

More Webcasts

Featured Activity

T&D World University 2008

Get expanded education, practical experience and unprecedented networking in 3 days at T&D World University, the Continuing Education Program for Utility Management, Engineers and Technical Professionals. October 27-29, 2008, Dallas, TX. With CEU-Earning Seminars, Specialized Tracks, 59+ Courses, T&D allows you to maximize your time, with minimal work interruptions. Bring your team to this productive learning environment.

Jobzone
  • November 2008 Issue
  • October 2008 Issue
  • September 2008 Issue
  • August 2008 Issue
  • July 2008 Issue
  • June 2008 Issue
  • May 2008 Issue

Browse Back Issues